<LOGO>
FM Transmitter Measurement Report
Created: 2024-06-13 03-06-08
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.40 MHz 5/5, 29 dBuV R-CB
Pilot RDS Phase Difference
6.6 kHz 2.5 kHz 82 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
15 kHz 43 kHz 18257 0,1041
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,1 dBr -0,80 dBr -0,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-CB " 250D 9 (Varied) 1 0 0 0 3:05, 13.06.2024
RT
"Ceske pisnicky ktere si zazpivate "
AF EON
88.2, 103.9, 106.4 MHz -
FM Scope Max at: 43 kHz MIN: 15 kHz % above 77 kHz: 0,1041 Acquired: 2024/06/13 3:06:05 Total samples: 18257 Equivalent time: 0:15:12 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: -0,4 dBr MIN: -1,1 dBr AVE: -0,80 dBr % above 0,2 dBr: 0,0 Last value: -0,8 dBr (2024/06/13 3:06:04) 02:52 02:54 02:56 02:58 03:00 03:02 03:04 03:06 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality